Skip to content

论文arXiv 2611.147629 天前

开源胫骨假肢旁路装置发布:10分钟适应期实现稳定步态数据采集 ​

本文由 AI 根据公开内容整理,可能有误,请以原文为准:Open-Source Transtibial Prosthetic Bypass Preserving Joint Alignment: Gait Learning and Kinematic Evaluation(arXiv 2611.14762)

核心内容 ​

针对现有胫骨假肢测试旁路需鞋垫补偿或侧向偏移导致步态失真问题,研究团队开发了一款保留部分膝关节矢状面自由度的开源机械旁路装置。实验显示6名健全受试者仅需约10分钟熟悉即可在无扶手支撑下完成跑步机行走,单腿支撑期占比27%(健侧45%),证实该装置具备快速部署与安全测试能力,有效解决了新型假肢原型在进入临床试验前缺乏安全、标准化人体测试平台的工程痛点。

基于OpenSim的运动学分析表明,旁路侧踝关节数据与真实胫骨截肢患者高度一致,但摆动期膝关节峰值屈曲角从61°显著降至36°(p<0.001),健侧髋关节活动范围从35°增至51°(p<0.01)。尽管未完全复刻病理步态,但该装置在极短学习周期内产出了高一致性运动学数据,且设计文件完全开源,可直接用于下肢机器人控制策略验证与传感器标定,大幅降低具身智能下肢研发早期的试错成本与伦理风险。

关键看点 ​

  • 快速适应性:健全受试者仅需10分钟熟悉即可无扶手稳定行走,单腿支撑期达27%,满足早期原型高频迭代测试需求
  • 运动学一致性:旁路侧踝关节运动学特征与真实截肢患者吻合,可作为下肢机器人感知与控制算法的标准化验证基准
  • 代偿机制量化:摆动期膝屈曲峰值降至36°且健侧髋ROM增至51°,揭示了非截肢者使用假肢时的生物力学代偿边界
  • 开源工程资产:完整机械设计开源,消除传统旁路对侧鞋垫与侧偏约束,保留膝关节矢状面自由度以提升测试保真度

工程与产业观察 ​

该开源旁路装置填补了下肢具身智能研发中“台架测试”与“临床截肢者试验”之间的验证空白。其10分钟快速适应特性与高一致性踝部数据,使其成为步态生成算法、阻抗控制策略及传感融合方案的理想低成本Debug工具。虽存在膝髋代偿差异,但作为预研阶段的安全沙盒,可显著加速下肢机器人从仿真到实人的迁移效率,建议相关团队将其纳入标准化测试流程。

英文摘要 (Abstract) ​

Prosthetic bypasses allow able-bodied individuals to walk with a prosthesis, enabling safe early-stage testing of new prosthetic devices before clinical trials. However, existing transtibial bypasses impose constraints, such as a contralateral shoe lift or a lateral offset of the prosthesis, and their effects on gait remain poorly documented. We present an open-source transtibial prosthetic bypass that preserves part of the sagittal knee mobility without these constraints. Six able-bodied participants familiarized themselves with the bypass for approximately 10~min, then walked on a treadmill with and without it, and joint kinematics were recorded with motion capture and then extracted with OpenSim. All participants were able to walk without handrail support, although single stance remained shorter on the bypass side (27% vs. 45% of the gait cycle). Bypass-side ankle kinematics were consistent with those reported for transtibial prosthesis users, whereas peak knee flexion during swing decreased from 61{\deg} to 36{\deg} (p<0.001) and hip range of the sound leg increased from 35{\deg} to 51{\deg} (p<0.01). Although gait with the bypass does not fully replicate that of prosthesis users, it yielded consistent gait patterns after only 10~min of learning. This bypass therefore provides a useful tool for the lower-limb prosthetics research community, facilitating preliminary experiments with able-bodied participants.

作者:Apolline de Vaulchier, Pablo Nocito, Yann Corbel, Nathana"el Jarrass'e

基于本页技术方向关联的整机参数、核心零部件、实测报告与同赛道选型横评。

外部来源

本页事实对应的公开页面,以原文为准。(点击将离开本站)

  1. arXiv 2611.14762:Open-Source Transtibial Prosthetic Bypass Preserving Joint Alignment: Gait Learning and Kinematic Evaluation ↗访问 2026-11-14